Data Center

Data is only a business asset when it's available. Continental designs, engineers, installs and maintains mission- critical systems that protect valuable information while ensuring constant access. We have performed electrical and structured cabling solutions for more than 1,100,000 square feet of mission-critical data centers.

Customers such as Allstate, Hewitt, Chicago Mercantile Exchange, Equinix, Northern Trust Bank, NAVTEQ, HSBC, CNA, Fidelity, Archipelago, Northlake Data Center — the largest computer center in the world — and others have trusted Continental to build and maintain their facilities with an integrated approach to power and data wiring. This enables us to efficiently use our resources, decrease time of construction and preserve our stringent quality controls.

Equinix CH3

330,000 sq ft new facility with 135,000 sq ft Co-Location Data Center Space. N+1 Power Distribution System including: 15 – 3MW, 35KV utility sub-stations, 17 – 2.5MW generators, 24 – 1000KVA UPS, 108 – 400A Automatic Static Transfer Switches, 108 – PDU’s, 432 RPP’s, circuit monitoring. The space was built in 3 sectors with Sector A & B completed in the original build-out and Sector C completed under a separate contract. 210,000 hours for the original build-out and 45,000 hours for Sector C.

Northlake Data Center

450,000 sq ft Build-out of a shelled building with 190,000 sq ft of Data Center Space. N+1 Power Distribution System including: 128KV Utility Yard, 11 – 3MW, 13KV Substations, 11 – 2.7MW generators, 31-750KVA & 2-270KVA UPS, 48 – 300KVA PDU, 56 – Modular Containers, circuit monitoring, CO-LO build-out. The project was completed in 210,000 labor hours.

Allstate Data Center

53,000 sq ft new building with 13,000 sq ft Data Center Space. 2(N+1) Power Distribution System including: 4 – Service Switchboards, 3 – 2.5MW generators, 8 – 750KVA UPS, 6 – PDU, Starline Bus for branch distribution, circuit monitoring. The project was completed in 50,000 labor hours.

Digital Realty Trust

12,000 sq ft Build-out of Data Center Space. 2N Power Distribution System including: 3 – 2.25MW generators, 6 – 625KVA UPS, 16 – 300KVA PDU. The project was completed in 28,000 labor hours.

6 Confidential Client Projects

369,800 sq ft total space, 118,650 Data Center Space. 55.6 Critical MW.

Data Center

Data is only a business asset when it's available. Continental designs, engineers, installs and maintains mission- critical systems that protect valuable information while ensuring constant access. We have performed electrical and structured cabling solutions for more than 1,100,000 square feet of mission-critical data centers.

Customers such as Allstate, Hewitt, Chicago Mercantile Exchange, Equinix, Northern Trust Bank, NAVTEQ, HSBC, CNA, Fidelity, Archipelago, Northlake Data Center — the largest computer center in the world — and others have trusted Continental to build and maintain their facilities with an integrated approach to power and data wiring. This enables us to efficiently use our resources, decrease time of construction and preserve our stringent quality controls.

Equinix CH3

330,000 sq ft new facility with 135,000 sq ft Co-Location Data Center Space. N+1 Power Distribution System including: 15 – 3MW, 35KV utility sub-stations, 17 – 2.5MW generators, 24 – 1000KVA UPS, 108 – 400A Automatic Static Transfer Switches, 108 – PDU’s, 432 RPP’s, circuit monitoring. The space was built in 3 sectors with Sector A & B completed in the original build-out and Sector C completed under a separate contract. 210,000 hours for the original build-out and 45,000 hours for Sector C.

Northlake Data Center

450,000 sq ft Build-out of a shelled building with 190,000 sq ft of Data Center Space. N+1 Power Distribution System including: 128KV Utility Yard, 11 – 3MW, 13KV Substations, 11 – 2.7MW generators, 31-750KVA & 2-270KVA UPS, 48 – 300KVA PDU, 56 – Modular Containers, circuit monitoring, CO-LO build-out. The project was completed in 210,000 labor hours.

Allstate Data Center

53,000 sq ft new building with 13,000 sq ft Data Center Space. 2(N+1) Power Distribution System including: 4 – Service Switchboards, 3 – 2.5MW generators, 8 – 750KVA UPS, 6 – PDU, Starline Bus for branch distribution, circuit monitoring. The project was completed in 50,000 labor hours.

Digital Realty Trust

12,000 sq ft Build-out of Data Center Space. 2N Power Distribution System including: 3 – 2.25MW generators, 6 – 625KVA UPS, 16 – 300KVA PDU. The project was completed in 28,000 labor hours.

6 Confidential Client Projects

369,800 sq ft total space, 118,650 Data Center Space. 55.6 Critical MW.